Fire alarm trouble signal.
Fire alarm panel trouble signal.
Many of the messages you see displayed here indicate a fault with your system that may require immediate attention and service.
A supervisory signal was used to indicate that some other protection system monitored by the fire alarm system was off normal.
It means that something in the fire alarm is broken.
Another signal is the trouble signal or trouble condition.
Some fire alarm panels may indicate the type of fire alarm trouble and its location.
The reset button only resets the panel after a fire alarm.
Here are some of the common reasons for a trouble signal.
When fire alarm panels are in trouble condition it can be difficult to find the root cause of the problem.
A trouble signal will also have a yellow light or led lit on the fire panel and there will be a slower beeping tone sounding from the panel.
Here s an explanation of what each fire alarm panel signal means.
It could be a loss of power.
In the past fire alarm terminology was fairly simple.
With any of these signals most fire panels will also have a digital display that will tell you what type of signal is active.
Trouble signals occur due to ground faults circuit problems battery faults or other failures within the system.
At this point the system will send a signal to the central station and clear your communication failure.
Trouble supervisory and alarm.
If this does not work you ll need a service call so that a trained technician can assess and fix the problem.
Something is not normal and it needs to be fixed.
3 a trouble signal was an indication that some part of the fire alarm system was broken or off normal.
Some wiring from the control panel to the devices in the house is supervised for integrity.
There are three basic categories for fire alarm panel signals.
Watch this video as orr vp of engineering lee kaiser walks us through the common causes for many trouble signals and the.
It will not reset any trouble.
So it could be oh gosh it could be an open circuit where a wire s broken and we don t have a continuous electrical pathway back to the panel.
For some more advanced systems the panel may indicate the kind of problem and where it is located.
A fire alarm trouble signal is generally yellow and indicates there s an operational issue.
Common fire alarm trouble indications.
Trouble signal a trouble signal is typically designated by a yellow light and means that there is an operational issue.
Potter electric signal company is a st.
Louis missouri based manufacturer of sprinkler monitoring devices fire alarm systems and corrosion solution products.